Anhuang bụ ọkachamara na Deadbreak Connector, anyị na-enye Dead break Connector dị elu.
● Sistemụ njikọ mkpuchi nkewa maka sistemụ nkesa dị n'elu; ANSI / IEEE Std386-2006600V
● Jaketị semiconductor a na-ekpughere ekpughere maka eriri voltaji dị elu na njikọ mkpuchi nkewa;
● Eriri ike e tinyere n'ime ihe mkpuchi na ihe ndị ọzọ ha nwere voltaji a tụrụ anya ya karịa 1 kV (Um = 1.2 kV) ruo 30 kV (Um - 35 kV);
● Usoro nnwale maka ngwa maka eriri ike nwere voltaji a tụrụ aro site na 6 kV (Um = 7.2 kV) ruo 30 kV (Um = 35 kV);
●Eriri ike ndị a na-ekpuchighị ekpuchi na ihe ndị ọzọ ha nwere voltaji a na-enye ọkwa site na 1 kV (Um = 1.2 kV) ruo 35 kV (Um = 40.5 kV).
● Nhazi mkpuchi nke akụrụngwa nnyefe na nkesa voltaji dị elu GB/T4109-1999
● Ọnọdụ teknụzụ nke ikesa voltaji dị elu;
● Ihe njide oxide nke na-enweghị oghere;
● Eriri ike nwere cone ndọtị - Nkewa na-edobe nha aka uwe na ihe ndị a na-ekewapụ iche maka Um dị n'okpuru 35 kV DIN 47636-7-1990.
A na-eji 15kV/24kV 600A Class T Deadbreak Connector kwụsị eriri voltaji dị elu n'okpuru ala gaa na transformers, switches, switchgear na ngwaọrụ ndị ọzọ. A na-echebe ya nke ọma, a na-etinye ya n'ime mmiri. Sistemụ anyị na-enye ebe nnwale capacitive pụrụ iche dịka ebe nnwale na njikọ ikpere aka 200A. Nke a na-enye ohere iji ihe ngosi mmejọ. Njikọ T gụnyere njikọ eriri T na ihe ndọtị ibu break bushing. Ha na-enyekwa ebe dị mma maka ihe njide MOVE ma ọ bụ ikpere aka ala. Ngalaba ihe nduzi ha dị bụ 25-500m² maka eriri 24kV.
| ihe | Data 15kV | Data 25kV | Data 35kV |
| Voltaji ọrụ na-aga n'ihu | 8.7kV/14.4kV | 15.2kV 26.3kV | 26kV/35kV |
| Voltaji na-eguzogide AC | 45kV/1 nkeji | 55kV/5 nkeji | 117kV/5min |
| DC na-eguzogide voltaji | 53kV/nkeji iri na ise | 78kV/15m na | 104kV |
| 1.5/50 μs Ọkụ m na voltaji kwụ ọtọ | 95kV | 125kV | 215kV |
| Voltaji mwepụ nke akụkụ | 13kV | 22kV | 45kV |
| ihe | 200AMP | 600AMP |
| Ibu ọrụ ugbu a | Dị na 14.4kV na 200A ugboro iri n'okpuru ọrụ na-agbaji ma mechie |
|
| Emechiri nsogbu ugbu a | Dị na 14.4kV, 1000N0.175 otu ugboro n'okpuru site na ọrụ mechiri emechi |
|
| Ebe a na-ekpo ọkụ ugbu a | 16kA 1s | 30kA 2s |
| Iguzogide elu ugbu a | 10kA | 105kA |

| Nọmba ntụaka. | Ngalaba obe nke onye nduzi (mm²) | Mgbatị nke mkpuchi (mm) |
| AH TT 24/600-35 | 35 | 18.6 |
| AH TT 24/600-50 | 50 | 19.6 |
| AH TT 24/600-70 | 70 | 21 |
| AH TT 24/600-95 | 95 | 22.6 |
| AH TT 24/600-120 | 120 | 24.2 |
| AH TT 24/600-150 | 150 | 25.6 |
| AH TT 24/600-185 | 185 | 27.2 |
| AH TT 24/600-240 | 240 | 28.7 |
| AH TT 24/600-300 | 300 | 31.1 |
| AH TT 24/600-400 | narị anọ | 33.2 |