MV Switchgear akụrụngwa

  • vacuum interrupter

    agụụ interrupter

    Onye na-egbochi agụụ na-eji seramiiki dị ka ikpuchi mkpuchi, ihe a na-akpọtụrụ bụ alloy CuCr, ihe owuwu magnetik ogologo oge, na ikike dị elu, ọkwa mkpuchi dị elu, ike na-agwụ ike, ogologo ndụ, obere obere na mmezi dị mfe, Ọ dịghị mgbawa ihe egwu, enweghi mmetọ, obere mkpọtụ na ihe ndị ọzọ. Main oru oke Uru Gosiri voltaji 12kV Gosiri ugbu a 630A Gosiri ugboro 50Hz Gosiri obere oge ike ugboro idi voltaji (1 min) 42k ...
  • Indoor SF6 for switchgear 10KV 630A Gas Insulated Load Break Switch LBS Indoor Isolating switch

    Ime ụlọ SF6 maka switchgear 10KV 630A Gas gwara mmanụ Ibu Ibu ezumike Gbanye LBS Indoor Anọrọ iche mgba ọkụ

    Ojiji nke onodu gburugburu ebe obibi: 1. Elu: ≤2000m; Ala ọma jijiji ike: ọ bụghị ihe karịrị asatọ 2. Ọnọdụ ikuku: adịghị elu karịa + 40 ℃, ọ bụghị ihe na-erughị -30 ℃. Onu ogugu kwa ubochi nke iru mmiri kariri 90%, onu ogugu kwa ubochi kariri 90%. 3. Ebe echichi nwere vibration ugboro ugboro na ime ihe ike adịghị mma maka ebe echichi nwere alụlụ mmiri, gas, kemịkalụ kemịkalụ kemịkalụ, nnu nnu, uzuzu na unyi, ọkụ na mgbawa mgbawa nke doro anya na-emetụta perfo ...
  • Incoming operating mechanism for gas insulated switchgear

    Na abata na-arụ ọrụ usoro maka gas gwara mmanụ

    SF6 gwara mmanụ ngwa ngwa: Manual / Motor: A, hard interlock / B, soft interlock Technical Parameters: Content Unit Parameter Gbanye Kpọtụrụ ọkọlọtọ N 190-210 Open tri-phase dissimilar ms ms2 Close tri-phase dissimilar ms ≤2 Oping nkezi ọsọ m / s 3-6 Na-emechi nkezi ọsọ m / s 4-6 Tri-adọ ibiaghachi ọkọlọtọ m / s ≤2 atọ-adọ mmepụta n'akuku Celsius 88 Celsius Mechanical ndụ Times 10000 Operation ike N -110 ịbịaru:
  • outgoing mechanism

    oku usoro

    SF6 gwara mmanụ Switchgear Ngwa: Manual / Motor: A, hard interlock / B, soft interlock Teknụzụ oke: Content Unit Parameter Gbanye Kpọtụrụ ọkọlọtọ N 80-190 Open tri-phase dissimilar ms ≤2 Close tri-phase dissimilar ms ≤2 Opening average ọsọ m / s 3-6 Na-emechi nkezi ọsọ m / s 4-6 Tri-adọ ibiaghachi ọkọlọtọ m / s ≤2 atọ-adọ mmepụta n'akuku Celsius 88 Celsius Mechanical ndụ Times 10000 Operation ike N -110 ịbịaru:
  • 12kV 630A loadbreak switch

    12kV 630A loadbreak mgba ọkụ

    Nka na ụzụ teknụzụ 12KV ọdịnaya nkeji nkeji volta KV 12 gosiri ugboro ole HZ 50 gosiri ego A 630 gosiri mkpụmkpụ sekit na-eguzogide cu 20 mgbazinye KA 20/25 gosiri ọnụ ọgụgụ dị elu na-eguzogide ugbu a KA 63 Gosiri obere oge elekere s 2 Gosiri obere oge elekere dị mkpirikpi KA 63 Mechnicial ndụ Oge 10000 Mepee triphase dissimilar ms ≤2 Imechi triphase dissimilar ms ≤2 eninggba ọsọ ọsọ ọsọ mis 3-6 losmechi nkezi ọsọ m / s 4-6 Ikuku arụ ọrụ nrụgide mgbaji: 22KV -28 ...
  • SF6 Insulated Load Break Switch

    SF6 gwara mmanụ Ibu Ibu ezumike Gbanye

    Isi Ihe Ntugharị ibu bụ ụdị ihe ntụgharị na ngwaọrụ nnweta arc dị mfe. Ọ na-eji gas SF6 eme ihe dị ka ihe mkpuchi mkpuchi na arc. Enwere ike iji ya dị ka mmechi na ịkwụsị ibu ugbu a ma bufee ugbu a. Enwere ike iji ya dị ka mmechi na imebi enweghị ibu. Ahịrị, ndị na-enweghị ibu ọkụ na ndị na-arụ ọrụ nchekwa, wdg, ọnọdụ ọnọdụ ọnọdụ atọ niile na-arụ ọrụ, ngbanye na ọrụ dị mfe na nhazi. Na mgbakwunye na ogologo ndụ, ike na-agbasa ...